1020 with std Belt Weighing software
- Weighing unit using passive sense, 1600 Samples per second
- 2,8” 320x240 Color
LCD display
- Panel Mount
DC
power supply:
-18 - 32Vdc (24Vdc
type) 4W max.
Inputs:
- 3 Inputs Optical
isolated, 1 common, 18 - 28 Vdc PNP or NPN
- Input 1 =
Start/Stop or Tachometer
- Input 2 = Dynamic
tarra
- Input 3 =
Zero
Outputs:
- 4 Outputs Isolated
PhotoMOS, 1 common, max. 35 Vdc or Vac, 0.5A nominal, 1A Surge PNP or
NPN
- Output 1 =
Alarm
- Output 2 =
Busy/Done
- Output 3 = Flow
OK
- Output 4 = Weight
Pulse
Analog
Output:
- Passive analog
output, the analog output
is used for Flow measurement or Flow
regulation
0 - 20
mA
4 - 20
mA
0 - 24
mA
4 - 24
mA
0 - 10 V (with a 500
ohm
resistor)
- For Certified or
Industrial applications
- USB-port for easy
calibrating via a PC
- Ethernet
communication
Communication can be
used for:
Ethernet:
- Communicate with
PC
- Communicate with
PLC (Ethernet IP, Fins and Modbus TCP protocol)
- Communicate with
other PENKO Flex devices with Ethernet (PENKO TP protocol)
-
Printing